Arista Fan Status Test
This test monitors the fans in the target Arista Switch and reports the status of the fans, temperature and the status of air flow in the fans. Using this test, administrators can keep a check on the fans that are currently malfunctioning.
Target of the test : Arista Switch
Agent deploying the test : An external agent
Outputs of the test : One set of results for the each fan on the target Arista Switch
Parameter | Description |
---|---|
Test period |
How often should the test be executed |
Host |
The IP address of the Arista Switch that is being monitored. |
SSH Port |
Besides SNMP, this test also uses the Arista Switch CLI to pull metrics. To run the CLI commands, the test first needs to establish an SSH connection with the Arista Switch. To enable the test to establish this connection, specify the SSH Port here. |
SSH Username, SSH Password, and Confirm Password |
As stated earlier, this test also uses the Arista Switch CLI to pull metrics. To use the CLI, the test first needs to connect to the Arista Switch via SSH, and then run commands using CLI. For running the commands, this test requires the privileges of a valid SSH user with permission to run the CLI commands. Specify the user name and password of such a user against SSH UserName and SSH Password text boxes, and confirm the password by retyping it in the Confirm Password text box. |
Timeout |
Specify the duration (in seconds) within which the SNMP query executed by this test should time out in this text box. The default is 10 seconds. |
Measurement | Description | Measurement Unit | Interpretation | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Status |
Indicates the current status the fans. |
|
The values that this measure can report and their corresponding numeric values are as follows:
Note: By default, this measure reports one of the Measure Values listed in the table above to indicate the current status of this fan. The graph of this measure however, is represented using the corresponding numeric equivalents only. |
||||||||||
Temperature |
Indicates the ambient temperature the fans. |
Celsius |
The temperature of the fans should be within admissible range. A sudden increase in the temperature of the fans indicate that the fans are malfunctioning. |
||||||||||
Airflow |
Indicates the status of air flow in the fans. |
|
The values that this measure can report and their corresponding numeric values are as follows:
Note: By default, this measure reports one of the Measure Values listed in the table above to indicate the status of air flow in the fans. In the graph of this measure however, the same is represented using the corresponding numeric equivalents only. |