CAM Payment Records Test
Dunning is a part of receivables management and becomes active as soon as a customer fails to pay an invoice on time. Intelligent dunning processes provide support in securing the liquidity of companies through the administration of payment reminders in the case of overdue invoices. CAM helps to integrate all the dunning procedures as digital processes. For this, CAM is connected to your accounting system. When an invoice becomes overdue, CAM intervenes to manage the process. The system suggests measures according to your criteria and performs them automatically if desired. This is made possible by putting individual customers into dunning groups. In this way, each individual customer can be allocated a process with measures such as initiating telephone payment reminders, dunning letters or passing on to a debt collection agency. CAM makes use of the payment records for performing the dunning process. The payment records are calculated using CAM software to find out any overdue in the payment. However, if CAM takes more time to calculate the payment records, it would cause a bitter user experience that can lead to loss of customer interest in the application usage. For this reason, it is really essential to monitor the calculation time of payment records by the application and alert administrators on any slowdowns or setbacks in a timely manner.
This test tracks the average rate at which payment records are calculated, and the 75th, 95th, 99th and 999th percentile value of calculation time. In addition, this test also reports the mean rate, median and standard deviation of the calculation times, and the number of payment records calculated and yet to be calculated. These statistical measures help administrators to analyze the calculation time of payment records on the application and promptly detect any deviations before user experience is negatively impacted.
Target of the test : A CAM Payment System
Agent deploying the test : A remote agent
Outputs of the test : One set of results for the target CAM Payment System being monitored.
Parameter | Description |
---|---|
Test Period |
How often should the test be executed. |
Host |
The host for which the test is to be configured. |
Port |
The port number at which the target application listens. The default is 7077. |
URL |
In this text box, specify the URL to be accessed by this test for extracting the CAM Payment System's performance statistics. |
Username |
Specify the Username for accessing the URL specified in the URL text box. |
Password |
Specify the Password of the above mentioned user in this text box. |
Confirm password |
Confirm the password by retyping it here. |
Measurement |
Description |
Measurement Unit |
Interpretation |
---|---|---|---|
Calculation time 1 minutes |
Indicates the average rate at which payment records have been calculated during the last 1 minutes. |
Hz |
|
Calculation time 5 minutes |
Indicates the average rate at which payment records have been calculated during the last 5 minutes. |
Hz |
|
Calculation time 15 minutes |
Indicates the average rate at which payment records have been calculated during the last 15 minutes. |
Hz |
|
Calculation time 75 percentile |
Indicates the 75th percentile value of time taken by the application to calculate the payment records. |
Seconds |
This measure indicates that the calculation time lies below this value 75% of the time. |
Calculation time 95 percentile |
Indicates the 95th percentile value of time taken by the application to calculate the payment records. |
Seconds |
This measure indicates that the calculation time lies below this value 95% of the time. |
Calculation time 99 percentile |
Indicates the 99th percentile value of time taken by the application to calculate the payment records. |
Seconds |
This measure indicates that the calculation time lies below this value 99% of the time. |
Calculation time 999 percentile |
Indicates the 999th percentile value of time taken by the application to calculate the payment records. |
Seconds |
This measure indicates that the calculation time lies below this value 99.9% of the time. |
Calculation time count |
Indicates the number of payment records that have been calculated since last CAM restart during the last measurement period. |
Number |
|
Calculation time minimum |
Indicates the minimum time taken by the application to calculate the payment records. |
Seconds |
|
Calculation time maximum |
Indicates the maximum time taken by the application to calculate the payment records. |
Seconds |
|
Calculation time mean rate |
Indicates the mean rate at which payment records was being calculated. |
Hz |
|
Calculation time median |
Indicates the median value of payment record calculation times. |
Seconds |
|
Calculation time standard deviation |
Indicates the standard deviation of payment records calculation times. |
Seconds |
|
Payment records |
Indicates the number of payment records calculated during the last 24 hours. |
Number |
|
Payment record check |
Indicates the number of payment records yet to be calculated. |
Number |
|