v7000 Enclosure Battery Status Test
Within a control enclosure, each power supply unit (PSU) contains a battery. The battery is designed to enable the IBM Storwize V7000 system to perform a memory dump of the cache to internal disks in the event of both power inputs failing. If these batteries are defective or have reached end-of-life, the storage system may be unsuccessful in writing cached data to the disks in the event of a power failure; this may result in loss of critical data. To avoid this, potential battery failures should be proactively detected and intimated to administrators, so that the problem can be fixed before any data loss occurs. This is where the v7000 Enclosure Battery Status test helps. For each battery in the PSUs, this test reports the battery health, whether it has adequate charge or not, and whether/not it is reaching its end-of-life. This way, the test warns administrators of an impending battery failure, and enables them to take pre-emptive action to correct the issue.
Target of the test : An IBM Storwize v7000 storage system
Agent deploying the test : A remote agent
Outputs of the test : One set of results for each battery present in the enclosure of the IBM Storwize v7000 storage system being monitored.
Parameter | Description |
---|---|
Test Period |
How often should the test be executed. |
Host |
The host for which the test is to be configured. |
Port |
The port number at which the specified host listens to. By default, this is NULL. |
Timeout |
Specify the duration (in seconds) beyond which the test will timeout in the Timeout text box. The default value is 60 seconds. |
Measurement | Description | Measurement Unit | Interpretation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Battery status |
Indicates the current health status of this battery. |
|
This measure can report any of the following values:
The numeric values that correspond to the above-mentioned states are as follows:
Note: By default, this measure reports the above-mentioned Measure Values while indicating the status of this battery. However, in the graph of this measure, the same will be represented using the corresponding numeric equivalents only. |
||||||||||||
Charging Status |
Indicates the charging status of this battery. |
|
This measure can report any of the following values:
The numeric values that correspond to the above-mentioned measure values are as follows:
Note: By default, this measure reports the above-mentioned Measure Values while indicating the charging status of a battery. However, in the graph of this measure, the same will be represented using the corresponding numeric equivalents only. |
||||||||||||
Is recondition needed? |
Indicates whether this battery needs to be reconditioned or not. |
|
This measure reports the value Yes if the battery needs to be reconditioned and the value No if the battery requires reconditioning, but cannot be reconditioned due to one or more errors. The numeric equivalents of these values are mentioned in the table below:
Note: By default, this measure reports the above-mentioned Measure Values while indicating the reconditioning status of this battery. However, in the graph of this measure, the same will be represented using the corresponding numeric equivalents only. |
||||||||||||
Percent charged |
Indicates the current charge percentage of this battery. |
Percent |
A high value is desired for this measure. A value close to 100% could indicate that the battery charge is about to die. |
||||||||||||
Is end of life? |
Indicates whether this battery is reaching its end of life and needs to be replaced or not. |
|
This measure reports the value Yes if the battery is reaching its end of life and a value No if otherwise. The numeric equivalents of these values are mentioned in the table below:
Note: By default, this measure reports the above-mentioned Measure Values while indicating whether this battery is reaching its end of life or not. However, in the graph of this measure, the same will be represented using the corresponding numeric only. |